CONTACT US

Our Address

Science Avenue, High-tech Zone, Zhengzhou City, Henan Province, China

  • Understanding Motor Nameplate Information NEMA v/s IEC ...

    intermittent duty rating is typically expressed in minutes. # 12: HORSEPOWER Shaft horsepower is a measure of the motor's mechanical output rating, its ability to deliver the torque required for the load at rated speed. It is usually given as "HP" on the nameplate and is calculated as follows: Horsepower (hp) = [Motor Speed ×Torque (lb-ft ...

  • How to Size a Cone Crusher Motor

    Cone Crusher Motor Sizing. Hard limestone, having an impact strength of 15, is fed from a secondary crusher set at 3¼-in. open side setting, producing stone having 80 percent minus 3¼-in. The product of the secondary crusher is screened at 5/8-in. The screening results in 5 percent minus 5/8-in. material in the tertiary crusher feed.

  • Rock Crusher Motors - Definite Purpose Motors - Grainger ...

    Rock crusher motors are have extra high starting torque and run at low speeds to crush rock. They are totally enclosed to protect against dust and water jets. These motors are precision balanced to reduce overall system vibration during continuous use.

  • Advanced Design Rock Crusher Motors WorldWide Electric

    WorldWide Electric’s Advanced Design Rock Crusher motors are available in 250-600 HP and 1800 1200 rpm. This crusher duty motor features a TEFC enclosure with an IP55 rating, a 4140 high tensile steel radius cut shaft, high starting and breakdown torques, and a heavy duty end bell design.

  • How to Read a Motor Nameplate - VFDs

    Full Load Amp Rating . The FLA rating is the rate at which a motor will consume power at 100% of rated load and at rated and balanced voltage. This number is extremely important, especially when dealing with electrical components. The wiring, starter, circuit breaker, and thermal overloads are all sized based upon the full load amp rating.

  • The Hot Issue of Motor Temperature Ratings ECM

    In a T frame motor with Class B insulation, the extra 25°C of thermal capacity (Class B compared to Class A) accommodates the higher temperature rise associated with the smaller T frame motors. For example: A standard T frame motor might have a rating of 40°C ambient, 80°C temperature rise, and a 10°C hot spot allowance.

  • How to Size a Cone Crusher Motor

    Cone Crusher Motor Sizing. Hard limestone, having an impact strength of 15, is fed from a secondary crusher set at 3¼-in. open side setting, producing stone having 80 percent minus 3¼-in. The product of the secondary crusher is screened at 5/8-in. The screening results in 5 percent minus 5/8-in. material in the tertiary crusher feed.

  • Rock Crusher Motors - Definite Purpose Motors - Grainger ...

    Rock crusher motors are have extra high starting torque and run at low speeds to crush rock. They are totally enclosed to protect against dust and water jets. These motors are precision balanced to reduce overall system vibration during continuous use.

  • Crusher Motor – Premium w/ Cable - Air Cycle

    Crusher Motor – Premium w/ Cable. Motor For Bulb Eater® and Bulb Eater® 3. 1/5 Horsepower - 2 Amp – 120 Volts. Part Number: 330-416. Price: $289.00 More Less. Product Rating. Rating: 0. Reviews: 0 Write A Review. Reviews. There are currently no reviews for this product. Write A Review.

  • Motor HP, Amps and Wire/Conduit Size Table - Home - Telemet

    HP: Voltage: Amps: Wire Size: Conduit Size (Dia. Inches) 5: 480/3: 7 (3)#12 AWG+(1)#12 GND: 3/4" 10: 480/3: 14 (3)#10 AWG+(1)#12 GND: 3/4" 15: 480/3: 21 (3)#10 AWG+(1 ...

  • The Hot Issue of Motor Temperature Ratings ECM

    In a T frame motor with Class B insulation, the extra 25°C of thermal capacity (Class B compared to Class A) accommodates the higher temperature rise associated with the smaller T frame motors. For example: A standard T frame motor might have a rating of 40°C ambient, 80°C temperature rise, and a 10°C hot spot allowance.

  • Basics of motor nameplates Machine Design

    This motor is a modern standard T-Frame motor. Critical mounting dimensions for all manufacturers are as defined in NEMA Standard MG 1. • 445TC. This T Frame motor has a standard NEMA-defined C ...

  • LT Motor Starter - Buy LT Motor Starter Online at Best ...

    LT motor starters are the best in their range and are widely used owing to their optimum performance. You can choose your pick between LT DOL Starter 20-32 Amp For 20.0 HP Motor ML 2 and LT DOL Starter 11-18 Amp For 7.5 HP Motor MK1 DOL. Rest assured to get the most reasonable rates at Industrybuying as compared to other online platforms.

  • How do you size a VFD? Flow Control Network

    Let’s begin with the basics by learning how to read a motor nameplate. The nameplate in Figure 1 shows that motor current is based on the input voltage: volts (V) 230/460, full load amps (FLA) 13.4/6.7. This means the motor uses 13.4 FLA at 230 V AC while only using 6.7 full load amps at 460 V AC.

  • 2013 Motor Catalog - ESR Motor S

    Series ODP High Efficiency WPI High Efficiency WPII High Efficiency TEFC Dura-Bull TX® High Efficiency TEFC High Efficiency TEAAC High Efficiency Horsepower 200 to 900 HP 400 to 5000 HP 200 to 800 HP 100 to 2500 HP 450 to 5000 HP Voltage (60 Hz) 2300, 2300/4000, 4000, or 4160 V (Option for 6000 V) 2300, 2300/4000, 4000, or

  • Cable Size Calculation for LT HT Motors Electrical ...

    Cable derating Amp (269.28 Amp) is higher than full load current of load (41 Amp) = OK; Cable voltage Drop (0.032%)is less than defined voltage drop (5%) = OK; Cable short circuit capacity (28.20 KA) is higher than system short circuit capacity at that point (26.2 KA) = OK

  • Advanced Design Rock Crusher Motors WorldWide Electric

    WorldWide Electric’s Advanced Design Rock Crusher motors are available in 250-600 HP and 1800 1200 rpm. This crusher duty motor features a TEFC enclosure with an IP55 rating, a 4140 high tensile steel radius cut shaft, high starting and breakdown torques, and a heavy duty end bell design.

  • What Is An Ampere Hour Rating (Amp Hour or Ah) Of A ...

    Amp Hour = Current (I) x Discharge Time (T) Amp Hour = 10 amperes x 15 hours. Amp Hour = 150 Ah. Rating = 150 Ah @ 15 hours. Get it? Now for the example below, we will find how long a battery will last given its AH rating and the current needed by the system to function. A 12V AGM 35Ah Battery is used to supply power to a system with a current ...

  • Vaccum Circuit Breaker Electrical Automation LT India

    Sub-cubicle for system voltage 11kV and a short time current rating of 26.3kA Half panel for system voltage 11kV and short time current rating of 26.3kA and 40kA Half panel comes with an option of Copper/Aluminium bus-bar

  • SOFT STARTERS - NHP Electrical

    Crusher - Jaw Severe Mill - Hammer Severe Shredder Severe Crusher - Rotary Medium Mill - Roller Severe Slicer Light ... a 50 amp motor in 6 wire would use a PCS-030-480 V and the overload current setting would be set to 29 Amps. ... rating. The motor connected must have an FLC within this range. E.g: PCS-009-480 V has an overload range of

  • Basics of motor nameplates Machine Design

    This motor is a modern standard T-Frame motor. Critical mounting dimensions for all manufacturers are as defined in NEMA Standard MG 1. • 445TC. This T Frame motor has a standard NEMA-defined C ...

  • Advanced Design Rock Crusher Motors WorldWide Electric

    WorldWide Electric’s Advanced Design Rock Crusher motors are available in 250-600 HP and 1800 1200 rpm. This crusher duty motor features a TEFC enclosure with an IP55 rating, a 4140 high tensile steel radius cut shaft, high starting and breakdown torques, and a heavy duty end bell design.

  • Crusher Duty Motors - Baldor

    Baldor•Reliance Crusher Duty motors are designed for Belt-driven rock crushers, pellet mills, and other applications requiring motors rated for severe duty service and high starting torques. product features. High torque NEMA Design A electrical design exceeds NEMA Design C locked rotor, pull up and breakdown torques ...

  • LT Motor Starter - Buy LT Motor Starter Online at Best ...

    LT motor starters are the best in their range and are widely used owing to their optimum performance. You can choose your pick between LT DOL Starter 20-32 Amp For 20.0 HP Motor ML 2 and LT DOL Starter 11-18 Amp For 7.5 HP Motor MK1 DOL. Rest assured to get the most reasonable rates at Industrybuying as compared to other online platforms.

  • TECO-Westinghouse Motor Company Online Store - TECO ...

    cd2006r: max-ht hi torque crusher duty/tefc: 449tz: 200: 1200: 460: tefc: cd2506r: max-ht hi torque crusher duty/tefc: 5007c: 250: 1200: 460: tefc: cd30085r : 5806c ...

  • Vaccum Circuit Breaker Electrical Automation LT India

    Sub-cubicle for system voltage 11kV and a short time current rating of 26.3kA Half panel for system voltage 11kV and short time current rating of 26.3kA and 40kA Half panel comes with an option of Copper/Aluminium bus-bar

  • SOFT STARTERS - NHP Electrical

    Crusher - Jaw Severe Mill - Hammer Severe Shredder Severe Crusher - Rotary Medium Mill - Roller Severe Slicer Light ... a 50 amp motor in 6 wire would use a PCS-030-480 V and the overload current setting would be set to 29 Amps. ... rating. The motor connected must have an FLC within this range. E.g: PCS-009-480 V has an overload range of

  • What Is An Ampere Hour Rating (Amp Hour or Ah) Of A ...

    Amp Hour = Current (I) x Discharge Time (T) Amp Hour = 10 amperes x 15 hours. Amp Hour = 150 Ah. Rating = 150 Ah @ 15 hours. Get it? Now for the example below, we will find how long a battery will last given its AH rating and the current needed by the system to function. A 12V AGM 35Ah Battery is used to supply power to a system with a current ...

  • SPECIFIER GUIDE INTRODUCTION - Baldor

    A motor should be rated continuous duty if it operates at full load for 60 minutes or more in any 24 hour period. If the motor operates less than 60 minutes, it may be given an intermittent duty rating or a short time rating. In either case, the time designated is that time which will elapse before the motor reaches full operating temperature. 7.

  • How do you size a VFD? Flow Control Network

    Let’s begin with the basics by learning how to read a motor nameplate. The nameplate in Figure 1 shows that motor current is based on the input voltage: volts (V) 230/460, full load amps (FLA) 13.4/6.7. This means the motor uses 13.4 FLA at 230 V AC while only using 6.7 full load amps at 460 V AC.

  • TECO-Westinghouse Motor Company: Stock Motors Three ...

    Motor Repair; Engineering Services; Testing; company. Company Profile; Quality and Environmental ... Sort by Price; Sort by Date; Sort by Popularity; Sort by Rating; Show 12 Products. Show 12 Products; Show 24 Products; Show 36 Products; 2 Speed, 1 Winding, Variable Torque Totally Enclosed Fan Cooled, [CP] ... MAX-HT™ Low Voltage Crusher Duty ...

  • List of AMP Connectors Models Products TE Connectivity

    Search our portfolio of AMP Connectors Models Products and select your specifications. You can now buy select products directly on TE. We offer a wide array of products with applications across many industries. From standard solutions to custom designs, we offer reliable, cost-effective products for mechanical, electrical, digital, analog, miniature, and harsh environment requirements.

  • Contactor and Starter Ratings

    Amp Rating HP 230 VAC HP 460 VAC 1¾ 40 10 15 2½ 60 20 30 3½ 115 40 75 ... DP contactors are sized by the motor full-load amps (FLA) and locked rotor amps (LRA). FLA is the amount of current the motor draws at full speed, under full mechanical load, at rated voltage. LRA is the maximum current the motor will draw at the

  • LT Crushing Systems-MMH-DP-Final C2C - LT Construction

    Title: LT Crushing Systems-MMH-DP-Final C2C.cdr Author: Vasant Panchal Created Date: 1/18/2016 4:46:53 PM

  • How do you size a VFD? Flow Control Network

    Let’s begin with the basics by learning how to read a motor nameplate. The nameplate in Figure 1 shows that motor current is based on the input voltage: volts (V) 230/460, full load amps (FLA) 13.4/6.7. This means the motor uses 13.4 FLA at 230 V AC while only using 6.7 full load amps at 460 V AC.

  • Crusher Duty Motors - Baldor

    Baldor•Reliance Crusher Duty motors are designed for Belt-driven rock crushers, pellet mills, and other applications requiring motors rated for severe duty service and high starting torques. product features. High torque NEMA Design A electrical design exceeds NEMA Design C locked rotor, pull up and breakdown torques ...

  • SOFT STARTERS - NHP Electrical

    Crusher - Jaw Severe Mill - Hammer Severe Shredder Severe Crusher - Rotary Medium Mill - Roller Severe Slicer Light ... a 50 amp motor in 6 wire would use a PCS-030-480 V and the overload current setting would be set to 29 Amps. ... rating. The motor connected must have an FLC within this range. E.g: PCS-009-480 V has an overload range of

  • Contactor and Starter Ratings

    Amp Rating HP 230 VAC HP 460 VAC 1¾ 40 10 15 2½ 60 20 30 3½ 115 40 75 ... DP contactors are sized by the motor full-load amps (FLA) and locked rotor amps (LRA). FLA is the amount of current the motor draws at full speed, under full mechanical load, at rated voltage. LRA is the maximum current the motor will draw at the

  • How to Calculate Safe Electrical Load Capacities

    Motors have a nameplate rating that is listed on the side of the motor. It lists the type, serial number, voltage, whether it is AC or DC, the RPM's, and, most importantly, the amperage rating. If you know the voltage and amperage rating, you can determine the wattage or total capacity needed for the safe operation of that motor.

  • Category - TM Engineering

    The Terminator is designed and used by customers that need to process samples 24 hours a day, 7 days a week. It is a very heavy duty machine, equipped with a standard 5HP motor, with the option of a 7.5HP motor. The adjustment of the jaws is very simple and it has certain key components that are stronger making the maintenance a lot easier.

  • Vaccum Circuit Breaker Electrical Automation LT India

    Sub-cubicle for system voltage 11kV and a short time current rating of 26.3kA Half panel for system voltage 11kV and short time current rating of 26.3kA and 40kA Half panel comes with an option of Copper/Aluminium bus-bar

  • 3 PHASE MOTOR LOAD CALCULATION - YouTube

    Oct 28, 2018  In this video we calculate 3 phase induction motor load, as we know we need to run 3 phase motor, one starter, cable, circuit and all this component

  • kW to Amps - Conversion, formula, chart, convert and ...

    kW to Amps – Conversion, formula, chart, convert and calculator free. With this tool you can convert kW to Ampere or Viceversa Amp. to kW automatically, easily, quickly and for free. For greater ease we explain that formula is used for the calculation, how to convert from kW to Ampere in just 3 steps, some examples and a table with the main ...

  • Electrical Motors - Full Load Amps

    As a "rules of thumb" amps horsepower rating can be estimated to. 115 volts motor - single-phase : 14 amps/hp; 230 volts motor - single-phase : 7 amps/hp; 230 volts motor - 3-phase : 2.5 amps/hp; 460 volts motor - 3-phase : 1.25 amps/hp; Always check nameplate information before designing protective devices, wiring and switch gear.

  • LT Crushing Systems-MMH-DP-Final C2C - LT Construction

    Title: LT Crushing Systems-MMH-DP-Final C2C.cdr Author: Vasant Panchal Created Date: 1/18/2016 4:46:53 PM

  • Medium Voltage Solid State Starters 300 - 6,000 hp 2,300 ...

    Motor amps Motor “Kick” level and times Service factor Overload class select Stop via ramp, coast, or DC braking Decel ramp profile Slow speed operation (Jog simulation) ±3% accuracy Average current Input current at each phase (L1, L2, L3) Current imbalance % Ground fault current Average volts L1-L2, L1-L3, L2-L3 voltage Overload %

  • WEG's e-Technical Catalog

    WEG, the largest industrial electric motor manufacturer in the Americas is pleased to offer its customers our brand new e-Technical Catalog. Our objective is to help you find the exact product and its related information through different search methods.

  • Understanding Induction Motor Nameplate Information ECM

    Finally, when the motor is loaded to its full-load torque, the motor speed stabilizes (Point D). If the motor isn't driving anything, its speed goes up to its no-load speed or synchronous speed (Point E). For example, on a four-pole motor operating at 60 Hz, the no-load speed might be 1,799 RPM and synchronous speed would be 1,800 RPM.